Over the years I have found that people often err on the side of high performance, highly reliable data storage for an operating system partition but choose slow, “cost effective” storage for critical data stores.  I am amazed by how often I find this occurring and now, with the advent of hypervisors, I see the same behaviour being repeated there as well – compounding the previously existing issues.

In many systems today we deal with only a single storage array shared by all components of the system.  In these cases we do not face the problem of misbalancing our storage system performance.  This is one of the big advantages of this approach and a major reason why it comes so highly recommended.  All performance is in a shared pool and the components that need the performance have access to it.

In many cases, whether in an attempt at increased performance or reliability design or out of technical necessity, I find that people are separating out their storage arrays and putting hypervisors and operating systems on one array and data on another.  But what I find shocking is that arrays dedicated to the hypervisor or operating system are often staggeringly large in capacity and extremely high in performance – often involving 15,000 RPM spindles or even solid state drives at great expense.  Almost always in RAID 1 (as per common standards from 1998.)

What needs to be understood here is that operating systems themselves have effectively no storage IO requirements.  There is a small amount, mostly for system logging, but that is about all that is needed.  Operating system partitions are almost completely static.  Required components are loaded into memory, mostly at boot time, and are not accessed again.  Even in cases where logging is needed, many times these logs are sent to a central logging system and not to the system storage area reducing or even removing that need as well.

With hypervisors this effect is even more extreme.  As hypervisors are far lighter and less robust than traditional operating systems they behave more like embedded systems and, in many ways, actually are embedded systems in many cases.  Hypervisors load into memory at system boot time and their media is almost never needed again while a system is running except for logging on some occasions.  Because hypervisors are small in physical size even the total amount of time needed to completely read a full hypervisor off of storage is very small, even on very slow media, because the total size is very small.

For these reasons, storage performance is of little to no consequence for operating systems and especially hypervisors.  The difference between fast storage and slow storage really only impacts system boot time where the difference in one second or thirty seconds rarely would be noticed, if at all.  When would anyone perceive even several extra seconds during the startup of a system and in most cases, startups are rare events happening at most once a week during an automated, routine system reboot during a planned maintenance window or very rarely, sometimes only once every several years, for systems that are only brought offline in emergencies.  Even the slowest conceivable storage system is far faster than necessary for this role.

Even slow storage is generally many times faster than is necessary for system logging activities.  In those rare cases where logging is very intense we have many choices of how to tackle this problem.  The most obvious and common solution here is to send logs to a drive array other than the one used by the operating system or hypervisor.  This is a very easy solution and ultimately very practical in cases where it is warranted.  The other common and highly useful solution is to simply refrain from keeping logs on the local device at all and send them to a remote log collection utility such as Splunk, Loggly or ELK.

The other major concern that most people have around their operating systems and hypervisors is reliability.  It is common to focus more efforts on protecting these relatively unimportant aspects of a system rather than the often irreplaceable data.  However, operating systems and hypervisors are easily rebuilt from scratch when necessary using fresh installs and manual reconfiguration when necessary.  The details which could be lost are generally relatively trivial to recreate.

This does not mean that these system filesystems should not be backed up, of course they should (in most cases.)  But just in case the backups fail as well, it is rare that the loss of an OS partition or filesystem truly spells tragedy but only an inconvenience.  There are ways to recover in nearly all cases without access to the original data, as long as the “data” filesystem is separate.  And because of the nature of operating systems and hypervisors, change is rare so backups can generally be less frequent, possibly triggered manually only when updates are applied!

With many modern systems in the DevOps and Cloud computing spaces it has become very common to view operating systems and hypervisor filesystems as completely disposable since they are defined remotely via a system image or by a configuration management system.  In these cases, which are becoming more and more common, there is no need for data protection or backups as the entire system is designed to be recreated, nearly instantly, without any special interaction.  The system is entirely self-replicating.  This further trivializes the need for system filesystem protection.

Taken together, the lack of need around performance and the lack of need around protection and reliability handled primarily through simple recreation and what we have is a system filesystem with very different needs than we commonly assume.  This does not mean that we should be reckless with our storage, we still want to avoid storage failure while a system is running and rebuilding unnecessarily is a waste of time and resources even if it does not prove to be disastrous.  So striking a careful balance is important.

It is, of course, for these reasons that including the operating system or hypervisor on the same storage array as data is now common practice – because there is little to no need for storage access to the system files at the same time that there is access to the data files so we get great synergy by getting fast boot times for the OS and no adverse impact on data access times once the system is online.  This is the primary means by which system designers today tackle the need for efficient use of storage.

When the operating system or hypervisor must be separated from the arrays holding data which can still happen for myriad reasons we generally seek to obtain reasonable reliability at low cost.  When using traditional storage (local disks) this means using small, slow, low cost spinning drives for operating system storage, generally in simple RAID 1 configuration.  A real world example is the use of 5400 RPM “eco-friendly” SATA drives in the smallest sizes possible.  These draw little power and are very inexpensive to acquire.  SSDs and high speed SAS drives would be avoided as they cost a premium for protection that is irrelevant and performance that is completely wasted.

In less traditional storage it is common to use a low cost, high density SAN consolidating the low priority storage for many systems onto shared, slow arrays that are not replicated. This is only effective in larger environments that can justify the additional architectural design and can achieve enough density in the storage consolidation process to create the necessary cost savings but in larger environments this is relatively easy.  SAN boot devices can leverage very low cost arrays across many servers for cost savings.  In the virtual space this could mean a low performance datastore used for OS virtual disks and another, high performance pool, for data virtual disks.  This would have the same effect as the boot SAN strategy but in a more modern setting and could easily leverage the SAN architecture under the hood to accomplish it.

Finally, and most dramatically, it is a general rule of thumb with hypervisors to install them to SD cards or USB thumb drives rather than to traditional storage as their performance and reliability needs are so much less even than traditional operating systems.  Normally if a drive of this nature were to fail while a system was running it would actually remain running without any problem as the drive is never used once the system has booted initially.  It would only be during a reboot that an issue would be found and, at that time, a backup boot device could be used such as a secondary SD card or USB stick.  This is the official recommendation for VMware vSphere, is often recommended by Microsoft representatives for HyperV and is officially supported through HyperV’s OEM vendors and is often recommended, but not so broadly supported, for Xen, XenServer and KVM systems.  Using SD cards or USB drives for hypervisor storage effectively turns a virtualization server into an embedded system.  While this may feel unnatural to system administrators who are used to thinking of traditional disks as a necessity for servers, it is important to remember that enterprise class, highly critical systems like routers and switches last decades and use this exact same strategy for the exact same reasons.

A common strategy for hypervisors in this embedded style mode with SD cards or USB drives is to have two such devices, which may actually be one SD card and one USB drive, each with a copy of the hypervisor.  If one device fails, booting to the second device is nearly as effective as a traditional RAID 1 system.  But unlike most traditional RAID 1 setups, we also have a relatively easy means of testing system updates by only updating one boot device at a time and testing the process before updating the second boot device leaving us with a reliable, well tested fall back in case a version update goes awry.  This process was actually common on large UNIX RISC systems where boot devices were often local software RAID 1 sets that supported a similar practice, especially common in AIX and Solaris circles.

It should also be noted that while this approach is the best practice for most hypervisor scenarios there is actually no reason why it cannot be applied to full operating system filesystems too, except that it is often more work.  Some OSes, especially Linux and BSD are very adept at being installed in an embedded fashion and can easily be adapted for installation on SD card or USB drive with a little planning.  This approach is not at all common but there is no technical reason why, in the right circumstances, it would not be an excellent approach except for the fact that almost never should an OS be installed to physical hardware rather than on top of a hypervisor.  In those cases where physical installs are necessary then this approach is extremely valid.

When designing and planning for storage systems, remember to be mindful as to what read and write patterns will really look like when a system is running. And remember that storage has changed rather dramatically since many traditional guidelines were developed and not all of the knowledge used to develop them still applies today or applies equally.  Think about not only which storage subsystems will attempt to use storage performance but also how they will interact with each other (for example, do two systems never request storage access at the same time or will they conflict regularly) and whether or not their access performance is important.  General operating system functions can be exceedingly slow on a database server without negative impact, all that matters is the speed at which a  database can be accessed.  Even access to application binaries is often irrelevant as they too, once loaded into memory, remain there and only memory speed impacts ongoing performance.

None of this is meant to suggest that separating OS and data storage subsystems from each other is advised, it often is not.  I have written in the past about how consolidating these subsystems is quite frequently the best course of action and that remains true now.  But there are also many reasonable cases where splitting certain storage needs from each other makes sense, often when dealing with large scale systems where we can lower cost by dedicating high cost storage to certain needs and low cost storage to other needs and it is in those cases where I want to demonstrate that operating systems and hypervisors should be considered the lowest priority in terms of both performance and reliability except in the most extreme cases.

The History of Array Splitting

Much of the rote knowledge of the IT field, especially that of the SMB field, arose in the very late 1990s based on a variety of factors.  The biggest factors were that suddenly smaller and smaller businesses were rushing to computerize, Microsoft had gotten Windows NT 4 so stable that there was a standard base for all SMB IT to center around, the Internet era had finally taken hold and Microsoft introduce their certification and training programs that reshaped knowledge dissemination in the industry.  Put together, this created both a need for new training and best practices and caused a massive burst of new thinking, writing, documentation, training, best practices, rules of thumb, etc.

For a few years nearly the entire field was trained on the same small knowledge set and many rules of thumb became de facto standards and much of the knowledge of the time was learned by rote and passed on mentor to intern in a cycle that moved much of the technical knowledge of 1998 into the unquestioned, set-in-stone processes of 2012.  At the time this was effective because the practices were relevant but that was fifteen years ago, technology, economics, use cases and knowledge have changed significantly since that time.

One of the best examples of this was the famous Microsoft SQL Server recommendation of RAID 1 for the operating system, RAID 5 for the database files and another RAID 1 for the logs.  This setup has endured for nearly the entire life of the product and was so well promoted that it has spread into almost all aspects of server design in the SMB space.  The use of RAID 1 for the operating system and RAID 5 for data is so pervasive that it is often simply assumed without any consideration as to why this was recommended at the time.

Let’s investigate the history and see why R1/5/1 was good in 1998 and why it should not exist today.  Keep some perspective in mind, the gap between when these recommendations first came out (as early as 1995) compared to today is immense.  Go back, mentally, to 1995 and think about the equivalent gap at the time.  That would have been like using recommendations in the early Internet age based on home computing needs for the first round of Apple ][ owners!  The 8bit home computer era was just barely getting started in 1978.  Commodore was still two years away from releasing their first home computer (the VIC=20) and would go through the entire Commodore and Commodore Amiga eras and go bankrupt and vanish all before 1995.  The Apple ][+ was still a year away.  People were just about to start using analogue cassette drives as storage.  COBOL and Fortran were the only series business languages in use.  Basically, the gap is incredible.  Things change.

First, we need to look at the factors that existed in the late 1990s that created the need for our historic setup.

  1. Drives were small, very small.  A large database array might have been four 2.1GB SCSI drives in an R5 array for just ~6GB of usable storage space on a single array.  The failure domain for parity RAID failure was tiny (compared to things like URE fail rates.)
  2. Drive connection technologies were parallel and slow.  The hard drives of the time were only slightly slower than drives are today but the connection technologies represented a considerable bottleneck.  It was common to split traffic to allow for reduced bus bottlenecks.
  3. SCSI drive technology was the only one used for servers.  The use of a PATA (IDE it was called at the time) in a server was unthinkable.
  4. Drives were expensive per gigabyte so cost savings was the key issue, while maintaining capacity, for effectively all businesses.
  5. Filesystems were fragile and failed more often than drives.
  6. Hardware RAID was required and only basic RAID levels of 1 and 5 were commonly available.  RAID 6 and RAID 10 were years away from being accessible to most businesses.  RAID 0 is discounted as it has no redundancy.
  7. Storage systems were rarely, if ever, shared between servers so access was almost always dedicated to a single request queue.
  8. Storage caches were tiny or did not exist making drive access limitations pass directly onto the operating system.  This meant having different arrays with different characteristics to handle different read/write or random/sequential access mixes.
  9. Drive failure was common and the principle concern of storage system design.
  10. Often drive array size was limited by physical limitations so often array splitting decisions were made out of necessity, not choice.
  11. A combination of the above factors meant that RAID 1 was best for some parts of the system where small size was acceptable and access was highly sequential or write heavy and RAID 5 was best for others where capacity outweighed reliability and where access was highly random and read heavy.

In the nearly two decades since the original recommendations were released, all of these factors have changed.  In some cases the changes are cascading ones where the move from general use RAID 5 to general use RAID 10 has then causes what would have been the two common array types, RAID 1 and RAID 10, to share access characteristics so the need or desire to use one or the other depending on load type is gone.

  1. Drives are now massive.  Rather than struggling to squeeze what we need onto them, we generally have excess capacity.  Single drives over a terabyte are common, even in servers.  Failure domains for parity are massive (compared to things like URE fail rates.)
  2. Drive connections are serial and fast.  The drive connections are no longer a bottleneck.
  3. SATA is now common on servers skewing potential risks for URE in a way that did not exist previously.
  4. Capacity is now cheap but performance and reliability are now the key concerns for dollars spent.
  5. Filesystems are highly robust today and filesystem failures are “background noise” in the greater picture of array reliability.
  6. Hardware RAID and software RAID are both options today and available RAID levels include many options but, most importantly, RAID 10 is available ubiquitously.
  7. Storage systems are commonly shared making sequential access even less common.
  8. Storage caches are commonly and often very large.  512MB and 1GB caches are considered normal today making many arrays in 1995 fit entirely into memory on the RAID controller today.  With caches growing rapidly compared to storage capacity and the recent addition of solid state drives as L2 cache in storage in the last two years it is not out of the question for even a small business to have databases and other performance sensitive applications running completely from cache.
  9. Drive failure is uncommon and of trivial concern to storage system design (compared to other failure types.)
  10. Drive array size is rarely limited by physical limitations.
  11. The use of RAID 1 and RAID 10 as the principle array types today means that there is no benefit to using different array levels for performance tuning.

These factors highlight why the split array system of 1995 made perfect sense at the time and why it does not make sense today.  OBR10, today’s standard, was unavailable at the time and cost prohibitive.  RAID 5 was relatively safe in 1995, but not today.  Nearly every factor involved in the decision process has changed dramatically in the last seventeen years and is going to continue to change as SSD becomes more common along with auto-tiering, even larger caches and pure SSD storage systems.

The change in storage design over the last two decades also highlights the dangers that IT faces as a large portion of the field learns, as is common in engineering, basic “rules of thumb” or “best practices” without necessarily understanding the underlying principles that drive those decisions making it difficult to know when not to apply those best practices or, even more importantly, when to recognize that the rule no longer applies.  Unlike traditional mechanical or civil engineering where new advances and significant factor changes may occur once or possibly never over the course of a career, IT still changes fast enough that complete “rethinks” of basic rules of thumb are required several times through a career.  Maybe not annually, but once per decade or more is almost always necessary.

The current move from uniprocessing to multithreaded architectures is another similar, significant change requiring the IT field to completely change how system design is handled.